ESTCube-1 CW beacon (safe mode)

ESTCUBE
1 39161U 13021C   13127.51954931 -.00000050  00000-0  00000+0 0    17
2 39161 098.1290 205.9903 0008586 231.4152 242.5727 14.68885660    27

10:47 UTC es5e/s t wmtdccu zfhb6e tttt datttt ttfhfh 5n5ztt tttz tztt kn
10:50 UTC es5e/s t wmtdcew zfhb6e tttt dbtttt ttfhf5 5a5ntt tttz tztt kn
10:53 UTC es5e/s t wmtddnn zfhb6e tttt datttt ttfhfh 5b5att tttz tztt kn
10:56 UTC es5e/s t wmtde5w zfhb6e tttt dbtttt ttfhf5 5c5btt tttz tztt kn
10:59 UTC es5e/s t wmtdfen zfhb6e tttt datttt ttfhfh 5..dtt tttz tztt kn


09:12 UTC es5e/s t wmtc5et zfhb6e attt dntttt ttfsfs 5a5ntt tttz tztt kn
09:15 UTC es5e/s t wmtc6nz zfhb6e tttt datttt ttfsfs 5b5att ttt8 tztt kn
09:18 UTC es5e/s t wmtcm5t zf5bbe tttt dntttt ttfsfs 5c5btt tttz tztt kn

Operating mode            T       Operating mode (E=normal or T=safe)
Timestamp                 1366345184000   Timestamp
Error code 1              143     Error code 1
Error code 2              75      Error code 2
Error code 3              110     Error code 3
Time in safe mode         40960   Time in safe mode
Main bus voltage          4.3     Main bus voltage
CDHS processor A          0       0=OK, 1=FAULT
CDHS processor B          0       0=OK, 1=FAULT
CDHS bus switch           0       0=OK, 1=FAULT
COM 3v3 voltage line      0       0=OK, 1=FAULT
COM 5V voltage line       0       0=OK, 1=FAULT
PL 3v3 voltage line       0       0=OK, 1=FAULT
PL 5V voltage line        0       0=OK, 1=FAULT
CAM voltage               0       0=OK, 1=FAULT
ADCS voltage              0       0=OK, 1=FAULT
Battery A charging        0       0=OK, 1=FAULT
Battery A discharging     0       0=OK, 1=FAULT
Battery B charging        0       0=OK, 1=FAULT
Battery B discharging     0       0=OK, 1=FAULT
Secondary power bus A     0       0=OK, 1=FAULT
Secondary power bus B     0       0=OK, 1=FAULT
12V line voltage          0       0=OK, 1=FAULT
Regulator A 5V            0       0=OK, 1=FAULT
Regulator B 5V            0       0=OK, 1=FAULT
Line voltage 5V           0       0=OK, 1=FAULT
Regulator A 3V3           0       0=OK, 1=FAULT
Regulator B 3V3           0       0=OK, 1=FAULT
Line voltage 3V3          0       0=OK, 1=FAULT
Regulator A 12V           0       0=OK, 1=FAULT
Regultator B 12V          0       0=OK, 1=FAULT
Battery A voltage         4.3     battery.A.voltage
Battery B voltage         4.3     battery.B.voltage
Battery A temperature     3.14    battery.A.temperature
Battery B temperature     2.42    battery.B.temperature
Average power balance     0       average.power.balance
Firmware version number   0       Version number
Number of crashes         0       Number of crashes
Forwarded RF power        8       forwarded.RF.power
Reflected RF power        8       reflected.RF.power
Received signal strength  0       received.signal.strength

Leave a Reply