CP-6

17:59:10 UTC 437.364.9 MHz COMM A – OK
18:01:12 UTC 437.359.4 MHz COMM B – OK

16:21:34 UTC 437.3665 MHz COMM B
16:23:34 UTC 437.359.6 MHz COMM A
16:25:34 UTC 437.3537 MHz COMM B – OK
16:27:33 UTC 437.351.2 MHz COMM A – OK


2009-05-21 16:27:33.160 UTC: [26 Bytes KISS Frame (without CRC)]
   1 > C0 00 9C 6C 86 A0 40 40 E0 9C 6C 86 A0 40 40 61 03 F0 04 43 
  21 > 4F 4D 4D 20 41 C0 
.­.COMM A

2009-05-21 16:27:34.790 UTC: [148 Bytes KISS Frame (without CRC)]
   1 > C0 00 9C 6C 86 A0 40 40 E0 9C 6C 86 A0 40 40 61 03 F0 19 3F 
  21 > 04 08 0C 01 02 2E 1E D5 0B 05 46 A9 FF 2C C3 D0 3F 03 6C 93 
  41 > 20 1F C1 BD 03 07 52 53 2D 2D C1 9B 03 07 4D 61 3D 3E C1 BA 
  61 > 06 04 5D AD 1E 1E C2 04 00 B7 27 B9 B8 C1 10 01 0A 0F 04 00 
  81 > 30 30 30 B8 B8 8B C7 6A 0E FD FF 1C E7 8B C7 6A 0E F2 FF 6E 
 101 > E4 01 01 00 00 04 66 26 08 43 FF FF FF FF 38 CD 08 39 0E 39 
 121 > FF FF 00 00 0C 01 02 2C 1E FD C8 C6 00 00 6F 32 BF 01 2E 34 
 141 > 1C 0A 00 00 78 00 42 C0 
=====================================================
Sensor Snapshot:     Packet Type: 25    Sequence Number: 1087

    JP5:
        Solar Panel Voltage: 5.012 V
        Solar Panel Current: 20.221 mA
        Magnetometer Current: 9.191 mA
        Magnetometer A: 70
        Magnetometer B: 169
        Internal Temp: -31.207 degC
        External Temp: 18.710 degC
        3V SP: 3.059 V
        
    JP6:
        Solar Panel Voltage: 4.894 V
        Solar Panel Current: 115.809 mA
        Magnetometer Current: 5.515 mA
        Magnetometer A: 108
        Magnetometer B: 147
        Internal Temp: 27.757 degC
        External Temp: 28.659 degC
        3V SP: 3.027 V
        
    JP7:
        Solar Panel Voltage: 4.447 V
        Solar Panel Current: 5.515 mA
        Magnetometer Current: 12.868 mA
        Magnetometer A: 82
        Magnetometer B: 83
        Internal Temp: 18.071 degC
        External Temp: 18.071 degC
        3V SP: 3.027 V
        
    JP8:
        Solar Panel Voltage: 3.647 V
        Solar Panel Current: 5.515 mA
        Magnetometer Current: 12.868 mA
        Magnetometer A: 77
        Magnetometer B: 97
        Internal Temp: 9.429 degC
        External Temp: 8.967 degC
        3V SP: 3.027 V
        
    JP9:
        Solar Panel Voltage: 4.376 V
        Solar Panel Current: 11.029 mA
        Magnetometer Current: 7.353 mA
        Magnetometer A: 93
        Magnetometer B: 173
        Internal Temp: 29.590 degC
        External Temp: 29.590 degC
        3V SP: 3.043 V
        
    CDH Data:
        RF Amp A Current: 36.765 mA
        RF Amp B Current: 0.000 mA
        3V CDH: 2.871 V
        RF Amp Temp: 22.137 degC
        3V Comm A: 2.902 V
        3V Comm B: 2.886 V
        VSUM: 4.541 V
        
    Power Data:
        CDH Current: 29.412 mA
        SPA Current: 1.838 mA
        SPB Current: 18.382 mA
        Comm A Current: 27.574 mA
        Comm B Current: 7.353 mA
        Payload Current: 0.000 mA
        CDH Temp: 16.238 degC
        Comm A Temp: 16.238 degC
        Comm B Temp: 16.238 degC
        3V SPA: 2.886 V
        3V SPB: 2.886 V
        
    Battery A Data:
        Prot Byte: DISCHARGING_ENABLED CHARGING_ENABLED CHARGE_PROTECTION CELL_OVERVOLTAGE_FAULT (0x-75)
        Status Byte: 199
        Voltage: 4.138 V
        Temp: 14.000 degC
        Currrent: -5.000 mA
        Acc Cur: -1593.000 mA
        
    Battery B Data:
        Prot Byte: DISCHARGING_ENABLED CHARGING_ENABLED CHARGE_PROTECTION CELL_OVERVOLTAGE_FAULT (0x-75)
        Status Byte: 199
        Voltage: 4.138 V
        Temp: 14.000 degC
        Currrent: -10.000 mA
        Acc Cur: -1764.500 mA
        
    CDH:
        Status: SENSOR_SNAP_NOW (0x01)
        State: Pre Ops
        Reset Count: 0
        Payload Control: CHECK_PAYLOAD (0x04)
        
    Comm:
        Status: XCVR_CAL READY SEL_RX SEL_RF (0x66)
        CC1000 CAL: 38
        CC1000 POW: 8
        CC1000 RSSI: 67
        
    Payload:
        Status: TESTING EXECUTING NEED_SS NAMES_READY CHUNK_READY INFO_READY KILL_ME  (0x-1)
        Proc Temp: -31.207 degC
        3V PL: 4.000 V
        5V PL: 4.000 V
        
    Timers:
        Normal Ops: 576824
        Sensor Snap Rate: 57
        ADCS Snap Rate: 14
        Beacon Rate: 57
        CDH Snaps Left to Take: 65535
        ADCS Snaps Left to Take: 0
        
    Last Error:
        Timestamp: 21-May 18:32:33
        Error Code: -3
        Address: 0x0000c6c8
        
    I2C Stats:
        Accepted: 12911
        Rejected: 447
        Read: 13358
        Sent: 2588
        Resent: 0
        Failures: 120
        
    CDH NRL Status:
        NRL Control: TAKE_STATUS CHECK_POWER (0x42) 